home *** CD-ROM | disk | FTP | other *** search
/ Gold Medal Software 3 / Gold Medal Software - Volume 3 (Gold Medal) (1994).iso / graphics / pc3d20.arj / READ.ME < prev    next >
Text File  |  1994-06-15  |  14KB  |  302 lines

  1.  
  2.       ProtoCAD 3D  Ver 2.00    Copyright 1994, TRIUS, Inc.
  3.            P.O. BOX 249,  North Andover,  MA  01845
  4.     ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  5.             Orders ONLY!: 800-GO-TRIUS (800-468-7487)
  6.    Info: 508-794-9377   FAX: 508-688-6312   BBS: 508-794-0762
  7.  
  8.  This READ.ME file contains information about  ProtoCAD 3D that did 
  9.  not make it to the printed manual of Ver. 2.00. It also lists the 
  10.  files distributed with Ver 2.00, and explains how to upgrade from 
  11.  previous versions. 
  12.  
  13.  Please READ THIS FILE THOROUGHLY!  It contains very important 
  14.  information, and reading it now will probably save you time and 
  15.  trouble later on! 
  16.  
  17.  You can print this file by COPYing it to your printer with the 
  18.  following command: 
  19.  
  20.        copy READ.ME prn
  21.  
  22.  If you want to look at the other On-Disk ProtoCAD 3D documentation, 
  23.  see the file list below, which lists all of the documentation files, 
  24.  and see the section on the On-Disk User's Manual. 
  25.  
  26.  Shareware and the Association of Shareware Professionals
  27.  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  28.                 _______
  29.            ____|__     |               (tm)
  30.         --|       |    |-------------------
  31.           |   ____|__  |  Association of
  32.           |  |       |_|  Shareware
  33.           |__|   o   |    Professionals
  34.         -----|   |   |---------------------
  35.              |___|___|    MEMBER
  36.  
  37.  The shareware concept has made it possible for you to obtain extremely 
  38.  powerful software at a price you can afford, and it gives you the 
  39.  opportunity to try the software before you register. 
  40.   
  41.  Shareware is kept alive by YOUR support.
  42.  
  43.  Evaluate the program for 30-days and give copies to your friends for 
  44.  evaluation.  If, after the 30 days, you continue to use the program, 
  45.  then register it by sending us the registration/order form included in 
  46.  this help file or by calling 800-468-7487 (Orders Only!). You will 
  47.  receive the Latest version, Printed manual, 90-day free Technical 
  48.  Phone Support, BBS Technical Support, Newsletter, and Reduced price 
  49.  Upgrades.  
  50.      
  51.  In addition to that, the 'UNREGISTERED COPY' message will be 
  52.  eliminated from the screen and a tool bar with the most frequently 
  53.  used commands will take its place.  Registering will also get you the 
  54.  capability of using external script files to create series of TGA and 
  55.  PCX files for animation sequences. And, of course, it will get you the 
  56.  legal license to use the software beyond the 30-day evaluation period. 
  57.  
  58.   ╔═════════════════════════════════════════════════════════════╗  
  59.   ║ If you purchased a Disk, without a printed, bound, user's   ║ 
  60.   ║ manual, or you downloaded a copy from a BBS or other        ║ 
  61.   ║ service, or you got a copy of ProtoCAD 3D from a CD-ROM, or ║ 
  62.   ║ the program was pre-loaded on your computer, then you have  ║ 
  63.   ║ a 30-day evaluation shareware copy.  You need to purchase   ║ 
  64.   ║ a registered copy after the 30-day evaluation!              ║ 
  65.   ╚═════════════════════════════════════════════════════════════╝
  66.  
  67.  Support new developments in ProtoCAD 3D, register your copy today! 
  68.  
  69.  Thank you for your support!
  70.    
  71.  ProtoCAD 3D is produced by a member of the Association of Shareware 
  72.  Professionals (ASP).  ASP wants to make sure that the shareware 
  73.  principle works for you.  If you are unable to resolve a shareware-
  74.  related problem with an ASP member by contacting the member directly, 
  75.  ASP may be able to help.  The ASP Ombudsman can help you resolve a 
  76.  dispute or problem with an ASP member, but does not provide technical 
  77.  support for member's products.  Please write to the ASP Ombudsman at: 
  78.  
  79.        ASP Ombudsman
  80.        545 Grover Road 
  81.        Muskegon, MI  49442-9427
  82.  
  83.  or send a Compuserve message via CMail to ASP Ombudsman 70007,3536. 
  84.  
  85.  
  86.  Minimum Hardware Requirements
  87.  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  88.   -  386SX CPU (see note below)
  89.   -  EGA or better video capabilities (VGA, SVGA, VESA)
  90.   -  480k minimum free memory (RAM)
  91.   -  2 Mb EMS (see note below)
  92.   -  DOS 3.2 or later
  93.   -  3.5" Drive(s), or 5.25" HD Drive(s), or Diskette/Hard Disk combination
  94.     
  95. Note:  Though the program will run on an XT or a 286 based CPU, with 
  96.        only 640k RAM, a 386SX CPU or better and 2Mb EMS is strongly 
  97.        recommended for any serious work.
  98.  
  99.  
  100.  GETTING STARTED
  101.  ~~~~~~~~~~~~~~~
  102.  The information provided below is to help you start the program for 
  103.  your hardware configuration.  For more details about the operation of 
  104.  the program press the F1 (function) key once you have started the 
  105.  program. 
  106.  
  107.  Once installed (see below for installation procedure) ProtoCAD 3D is 
  108.  started from DOS using the command: 
  109.  
  110.   C:> PC3D /Option1/Option2/Option3/.....     [ENTER]
  111.  
  112.  where Option1, Option2, etc.  are options specifying the type of 
  113.  memory to use, the type of graphics video adapter, etc.  For a 
  114.  complete description of these options, please print and consult the 
  115.  on-disk user's manual.
  116.  
  117.  
  118.  Ordering Information
  119.  ~~~~~~~~~~~~~~~~~~~~
  120.  Remember that a shareware copy is an EVALUATION copy that you can use 
  121.  for up to 30 days.  If you continue to use the program, Registration 
  122.  and payment are Required!  You may register using the order form in the 
  123.  ORDER.ME file, or by calling TRIUS, Inc. and charging your purchase on 
  124.  your credit card. We suggest that you call, since prices are subject to 
  125.  change without notice. 
  126.  
  127.  You may also order your copy on-line by calling our TRIUS Support BBS 
  128.  at (508) 794-0762 [12/24/9600,N,8,1  - 24 hrs]. 
  129.  
  130.  If you live outside the US and Canada you may want to contact TRIUS, 
  131.  Inc. for a dealer in your country.  Purchasing through these dealers 
  132.  can save you the delay and inconvenience which may be involved in 
  133.  dealing with currency conversions and international shipping and in 
  134.  many cases will provide you with faster technical support. 
  135.  
  136.  
  137.  Files on the ProtoCAD 3D Distribution Disk(s)
  138.  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  139.   PC3D20.FLS   -  Compressed Archive
  140.   READ.ME      -  Start-Up instructions (This file)     
  141.   ORDER.ME     -  Ready-to-print order form  
  142.   LICENSE.DOC  -  Please Read This!!         
  143.   VENDOR.DOC   -  Info on Distributing Shareware Copies
  144.   INSTALL.EXE  -  Automated SetUp File       
  145.  
  146.  
  147.  Installation on Floppy or Hard Disk:  
  148.  ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  149.  The program will work if installed on 3.5" (720K or 1.44Mb) diskettes, 
  150.  or 5.25" HD (1.2 Mb) diskettes.  We recommend that the program is 
  151.  installed either on a hard disk, or a high density floppy diskette, 
  152.  since this will permit the help file, and other auxiliary files, to be 
  153.  available to the user.  
  154.  
  155.      If you Install and run ProtoCAD 3D from a floppy disk, without      
  156.      Expanded memory (EMS), or if the /NE command line switch is        
  157.      used, and you remove the ProtoCAD 3D program disk from  
  158.      the drive while the program is running, you will get an 
  159.      error message and will be instructed to re-insert the disk.
  160.    
  161.  * Place the ProtoCAD 3D original diskette in drive A: (or B:)
  162.  
  163.  * Make sure the current logged drive is A: (Type A:, or B:, and 
  164.    press ENTER, if it is not).
  165.   
  166.  * Type INSTALL and press [ENTER].  Then, follow the simple on-screen 
  167.    instructions to install your copy of the program on the desired disk(s) 
  168.    and/or subdirectory.
  169.  
  170.  
  171. Upgrading from Ver 1.1 or earlier
  172. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  173. If you are upgrading from an earlier version of the program, we 
  174. recommend that you install the program in the directory where the old 
  175. version resides, answering Yes when the installation program asks if 
  176. you want to overwrite the files.  Furthermore, it is recommended that 
  177. you delete the old configuration file (PC3D.CFG), in that directory 
  178. prior to running ProtoCAD 3D v2.00. 
  179.  
  180.  
  181. Windows Users
  182. ~~~~~~~~~~~~~
  183. ProtoCAD will work fine under Windows 3.1.  If you are going to run the 
  184. program in a windows environment, you may use the files PC3D.PIF and 
  185. PC3D.ICO which are extracted as part of the installation process.  It 
  186. should be noted that the PC3D.PIF file is setup to run the program in a 
  187. windowed mode.  For better program response, however, we recommend that 
  188. the PIF file is modified (using the Windows PIF Editor), to run in full 
  189. screen mode. 
  190.  
  191.  
  192.  On-Disk Documentation
  193.  ~~~~~~~~~~~~~~~~~~~~~
  194.  The installation process extracts a file called PC3D.MAN.  This is a 
  195.  ready-to-print formatted, User's manual for the program.  
  196.  
  197.  Following the installation, make sure that the PC3D.MAN file is 
  198.  indeed on your default directory.  Then, to print this manual: 
  199.  
  200.  (1)  Make sure that the your printer is ON  and there is enough 
  201.       paper in it (the manual is about 100 pages).
  202.  
  203.  (2)  From the DOS prompt, type
  204.  
  205.       COPY PC3D.MAN PRN and press [ENTER]
  206.  
  207.       Note that if your printer is connected to a SERIAL port,
  208.       then you need to use the command  COPY PC3D.MAN COM1, or
  209.       COPY PC3D.MAN COM2 (depending on which serial port your 
  210.       printer is connected to).
  211.   
  212.  
  213.  
  214. NOTES/ADDITIONS TO THE USER'S MANUAL
  215. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  216.  1. When a new view is selected, an image extents scan is made and the 
  217.     image is placed in the center of the screen (similar to performing 
  218.     an Image, All command), if the Auto Ctr toggle is ON.
  219.     
  220.  2. Identifying reference marks are placed in the center of facets.  This 
  221.     is particularly useful when trying to change the surface normal, since 
  222.     it permits you to select uniquely identified facets. 
  223.  
  224.  3. The limit on the number of points that can be accommodated when 
  225.     importing a WAV file, was increased to 8000.
  226.  
  227.  4. VGA 256-color and VESA color mapping is done using a 3,3,2 model, 
  228.     i.e., 3 bits are used for Green, 3 for Red and 2 for Blue.  Since 
  229.     there is not enough resolution (2 bits) for Blue, you might 
  230.     experience blue patches when rendering an 'almost' gray scale image.  
  231.     If that happens, select the Gray option in the Render sub-menu. 
  232.  
  233.  5. When rendering in 256 colors, the edges are NOT visible regardless of 
  234.     the setting selected in the Render, Edges sub-menu.
  235.  
  236.  6. The trackball employs an effective 'gimbal lock' mechanism.  If the 
  237.     image is rotated/rolled beyond a 90 degree angle, the  Yaw  angle 
  238.     automatically switches by 180 degrees. 
  239.  
  240.  7. As the observer distance (D) is reduced, and you move closer to the 
  241.     center of the image, you will observe some clipping of polygons that 
  242.     are effectively behind the focal length plane.  This normally occurs at 
  243.     about D=0.5.  You might need to render the image to re-orient 
  244.     yourself. 
  245.  
  246.  8. When attempting to print without EMS, the 32k-48k shadow buffer is 
  247.     used by the Z-buffer model to internally render the image in 
  248.     horizontal strips.  Since the buffer size is limited, the longer the 
  249.     strip (specified print width) the narrower the vertical strip size 
  250.     that can be accommodated.  When the calculated vertical size falls 
  251.     below 16 scan lines, the program will not render and will abort the 
  252.     printing process.  This limit will accommodate a 7.5 inch width at 
  253.     120 dots per inch resolution.  Under these conditions, if you want to 
  254.     increase the resolution, you'd have to reduce the specified print 
  255.     width.  For above example, if you wanted to use 240 dpi resolution, 
  256.     the specified width should be approximately 3.75 inches. 
  257.  
  258.  9. When creating TGA output files, the program requires approximately 
  259.     300k of EMS to render the image.  If it's not available, the TGA 
  260.     output menu is disabled and an appropriate error message will be 
  261.     issued. 
  262.  
  263. Modifications in Release 2.00a
  264. ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  265.  1. The {smooth_triangle....} option was implemented for POV output 
  266.     files, for all mesh type objects on layers 17-32 (spheres, extrusions, 
  267.     etc.)   This results in a smoother transition from facet to facet 
  268.     using the average sufrace normal of each facet bordering the 
  269.     vertex.  (No such smoothing takes place on layers 1-16).
  270.     
  271.  2. The {bounded_by.....}  option was implemented in the POV output 
  272.     files.  This results in a significant decrease in rendering time.
  273.     The {composite...} command is now used to group related objects 
  274.     rather the {object...} command.  This was necessary in order to 
  275.     make the {bounded_by...} command operational.
  276.  
  277.  3. The observer point coordinates, in the POV output file, are now 
  278.     reflective of the user selected observer coordinates.
  279.  
  280.  4. The observer point coordinates, while viewing an image in ProtoCAD, 
  281.     are now reflective of the user selected observer coordinates. 
  282.  
  283.  5. If you are using later versions of the POV program to ray trace 
  284.     images created with ProtoCAD, then the   +mv1.0   command line 
  285.     switch should be used (The command structure in the ProtoCAD created 
  286.     files conforms to ver 1.x of POV - see POV documentation for 
  287.     additional information). 
  288.  
  289.  6. A correction was made to the File, Config, Printer menu, to ensure 
  290.     that the printer driver selected by the user would stay selected 
  291.     after the menu was exited. 
  292.  
  293.  7. The on-screen "control cube" speed is now controlled by the SPDUP 
  294.     parameter under the File, Config, Default menu.  The default value is 
  295.     2 which should be fine for most users.  Increasing the value speeds 
  296.     up the control cube movement, while decreasing it to 1 or 0 slows it 
  297.     down for pin-point viewing accuracy. 
  298.          
  299. - End -
  300.  
  301.  
  302.